Type SHD-GC Round Mining Power Cable 2kV
Type SHD-GC Round Mining Power Cable 2kV Application
These SHD-GC heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps and mobile equipment where grounding conductors, a ground check conductor and metallic shielding are required.
This Type SHD-GC portable mining cable has excellent impact and abrasion resistance, and withstand exposure to oil, acids, alkalies, heat, moisture and most chemicals, Indent printed for easy identification Rope lay stranding for maximum flex life, cable core bound for superior flexibility and toughness.
Rated Voltage of 5Kv, 8Kv, 15Kv, 25Kv is available upon request.
Type SHD-GC Round Mining Power Cable 2kV Standard
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96
Type SHD-GC Round Mining Power Cable 2kV Construction
Conductor | Stranded annealed tinned copper conductor. |
Insulation | Ethylene Propylene Rubber (EPR). |
Insulation Shield | Tinned copper/textile braid. |
Ground Check Conductor | Tinned copper conductor with a yellow polypropylene insulation. |
Grounding Conductor | Tinned copper conductor. |
Jacket | Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black. Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request. Two-layer jacket with reinforcing fibre between the two layers can be offered as an option. |
Type SHD-GC Round Mining Power Cable 2kV Specification
Construction | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Jacket Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity |
No. of cores ×AWG/kcmil | AWG/ kcmil | AWG/ kcmil | mm | mm | mm | kg/km | A |
3×6 | 10 | 10 | 1.8 | 3.9 | 32.8 | 1682 | 93 |
3×4 | 8 | 10 | 1.8 | 3.9 | 35.6 | 2173 | 122 |
3×3 | 7 | 10 | 1.8 | 4.3 | 38.3 | 2500 | 140 |
3×2 | 6 | 10 | 1.8 | 4.3 | 40.4 | 2961 | 159 |
3×1 | 5 | 8 | 2.0 | 4.8 | 44.7 | 3549 | 184 |
3×1/0 | 4 | 8 | 2.0 | 4.8 | 47.2 | 4115 | 211 |
3×2/0 | 3 | 8 | 2.0 | 5.2 | 50.8 | 4844 | 243 |
3×3/0 | 2 | 8 | 2.0 | 5.2 | 54.1 | 5789 | 279 |
3×4/0 | 1 | 8 | 2.0 | 5.6 | 58.7 | 7024 | 321 |
3×250 | 1/0 | 6 | 2.4 | 5.6 | 63.8 | 8125 | 355 |
3×300 | 1/0 | 6 | 2.4 | 6.0 | 68.1 | 9517 | 398 |
3×350 | 2/0 | 6 | 2.4 | 6.0 | 71.4 | 10834 | 435 |
3×500 | 4/0 | 6 | 2.4 | 6.7 | 81.0 | 14614 | 536 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Please note that the above specifications are “general specifications” that pertain to the majority of our production. These specifications should only be used for general, informational purposes. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All specifications are subject to change without prior notice. All pictures shown are for illustration purposes only. Actual product may vary.
Reviews