Type G-GC Flat Portable Feeder Cable 2KV
Type G-GC Flat Portable Feeder Cable 2KV Application
Type G-GC cables are designed for use in industrial and light-to-medium duty mining applications. These cables are often used on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. This construction has a ground check as a safety mechanism to ensure the equipment is fully grounded.
Type G-GC cables are suitable for use in industrial and light- to medium-duty mining applications, heavy-duty service as power supply cable, power cable for mobile and portable electrical equipment at a continuous conductor temperature of 90°C. Type G-GC cables may be used in marina (wet) applications. Type G cables are suitable for use on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. Excellent flexibility, resistance to oils, solvents, ozone, aging, and abrasion.
This Type G-GC portable mining cable has excellent impact and abrasion resistance, and withstand exposure to oil, acids, alkalies, heat, moisture and most chemicals, Indent printed for easy identification Rope lay stranding for maximum flex life, cable core bound for superior flexibility and toughness.
Type G-GC Flat Portable Feeder Cable 2KV Standard
ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96
Type G-GC Flat Portable Feeder Cable 2KV Construction
Conductors | Stranded annealed tinned copper conductor. |
Insulation | EPR. |
Ground Check Conductor | Tinned copper conductor with a yellow insulation. |
Grounding Conductor | Tinned copper conductor with a green outer covering. |
Reinforcement | Synthetic yarn. |
Sheath | Extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered upon request. |
Options | Other jacket materials such as CSP/PCP/NBR/PVC are available upon request. Two-layer jacket with reinforcing fibre between the two layers can be offered as an option. |
Type G-GC Flat Portable Feeder Cable 2KV Specification
Construction | Grounding Conductor Size |
Ground Check Conductor Size |
Nominal Insulation Thickness |
Nominal Overall Diameter Height×Width |
Nominal Weight |
Ampacity |
No. of cores× AWG/kcmil |
AWG/kcmil | AWG/kcmil | mm | mm | kg/km | A |
3×6 | 8 | 8 | 1.5 | 16.8×42.4 | 1340 | 79 |
3×4 | 7 | 8 | 1.5 | 18.3×47.5 | 1750 | 104 |
3×3 | 6 | 6 | 1.5 | 19.8×52.8 | 2080 | 120 |
3×2 | 5 | 6 | 1.5 | 21.6×56.6 | 2415 | 138 |
3×1 | 4 | 6 | 2 | 24.4×63.5 | 3110 | 161 |
3×1/0 | 3 | 5 | 2 | 25.6×67.8 | 3675 | 186 |
3×2/0 | 2 | 5 | 2 | 27.7×68.1 | 4375 | 215 |
3×3/0 | 1 | 5 | 2 | 30.0×79.2 | 5230 | 249 |
3×4/0 | 1/0 | 5 | 2 | 31.5×83.8 | 6315 | 287 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Please note that the above specifications are “general specifications” that pertain to the majority of our production. These specifications should only be used for general, informational purposes. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All specifications are subject to change without prior notice. All pictures shown are for illustration purposes only. Actual product may vary.