Products

TFOI High Voltage Marine Power Cable

Material: Cu/Semi-Conduct/XLPE/Semi-conduct/Copper tape/XLPE/CWB/SHF1
Standard: IEC 60092
Application: TFOI HV Marine  Power cables are an armored cable for power distribution in a fixed installation in ships where cable protection is required.

TFOI High Voltage Marine Power Cable

TFOI High Voltage Marine Power Cable Application

TFOI HV Marine  Power cables are an armored cable for fixed installation in ships where cable protection is required. The TFOI cable has medium Voltage power distribution. TFOI cable can be installed and operated both indoors and outdoors. This cable has an operating temperature of 90°C and the operating voltage could be 3.6/6KV, 6/10KV, 8.7/15KV,12/20KV.

Cable Designation:
3.6/6kV TFOI, 6/10kV TFOI, 8.7/15kV TFOI, 12/20KV TFOI

Standard:
Design Guide: IEC 60092-350 and IEC 60092-353
Insulation material: IEC 60092-351, XLPE Sheath material: IEC 60092-359, SHF1
Flame retardant: IEC60332-1 and IEC 60332-3 Category A
Halogen content: IEC60754-1, 0.5%↓ Smoke emission: IEC 61034, 60%↑

TFOI High Voltage Marine Power Cable Construction

Classification Code Construction detail
Conductor Stranded plain annealed copper wires as per IEC 60228, Class 2
Conductor screen Semi-conducting layer (tape / compound)
Insulation T XLPE as per IEC 60092-351
Insulation screen – Non-metallic part : Semi-conducting layer (tape / compound)
– Metallic part: Copper tape with about 0.1mm thickness
– A suitable separator tape(s) may be applied over the metallic part
Cabling – Three metallic wrapped conductors shall be cabled
– Flame retardant & non-hygroscopic fillers may be used
– Suitable tape(s) may be applied on the cabled core
– A Filler may be applied to obtain a circular Cable
Inner covering F Halogen free compound
Armor O – Braid of pain annealed copper wire
– Coverage density: Min. 90%
Sheath I – SHF1 as per IEC 60092-359
– Sheath color: Red
Core identification Colored tape shall be inserted under the metallic screen
3C: Red, Yellow, Blue

TFOI High Voltage Marine Power Cable Specification

TFOI 3.6/6KV Technical Data

No. of
Cores
xNominal
Conductor
Area
Max. Conductor
Dia.
Nominal
OD
Tolerance Max. Conductor
Resistance
(at 20°C)
Cable
Weight
mm2 mm mm mm /km kg/km
1×10 4.2 19.6 0.9 1.830 580
1×16 5.3 20.5 0.9 1.150 670
1×25 6.6 21.8 1.0 0.727 800
1×35 7.9 23.2 1.0 0.524 940
1×50 9.1 24.5 1.0 0.387 1,100
1×70 11.0 26.5 1.1 0.268 1,380
1×95 12.9 28.6 1.2 0.193 1,700
1×120 14.5 30.4 1.2 0.153 2,000
1×150 16.2 32.0 1.3 0.124 2,320
1×185 18.0 34.4 1.3 0.0991 2,770
1×240 20.6 38.0 1.4 0.0754 3,530
1×300 23.1 41.2 1.5 0.0601 4,270
1×400 26.1 45.6 1.7 0.0470 5,410
1×500 29.2 48.9 1.8 0.0366 6,390
1×630 33.2 53.5 1.9 0.0283 8,030
3X10 4.2 35.4 1.4 1.830 1,620
3X16 5.3 38.4 1.5 1.150 2,030
3X25 6.6 41.4 1.5 0.727 2,470
3X35 7.9 44.2 1.6 0.524 2,930
3X50 9.1 47.6 1.7 0.387 3,510
3X70 11.0 51.9 1.9 0.268 4,390
3X95 12.9 56.6 2.0 0.193 5,470
3X120 14.5 60.4 2.1 0.153 6,450
3X150 16.2 64.1 2.2 0.124 7,490
3X185 18.0 68.3 2.3 0.0991 8,850
3X240 20.6 75.4 2.6 0.0754 11,080

​Please Note:
More Specifications, please check with our sales.
Photographs are not to scale and do not represent detailed images of the respective products. The above specifications are “general specifications” that pertain to the majority of our products. These specifications should only be used for general, informational purposes. The measurement/size of the goods delivered may be different from the data in the above table, please check with us when order placed.

Reviews

There are no reviews yet.

Be the first to review “TFOI High Voltage Marine Power Cable”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.