FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable
FR-TPYC Shipboard Fire Resistant Armored Power&Lighting Cable Application
FR-TPYC JIS C 3410 Shipboard Armored Power&Lighting Cable is intended for power, lighting on shipboard, marine, and oil, gas off-shore platform where requires fire resistant features to ensure man safe and circuit integrity.
JIS C 3410 Shipboard Fire Resistant Armored Cable Standards and Designation
Designation: FR-DPYC, FR-TPYC, FR-FPYC
STANDARDS: JIS C 3410-2010,
Fire Resistant: IEC 60331
FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable Construction
Conductor | D(T,F,5,6,10) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
Insulation | P | 85°C EPR as per JIS C 3401 |
Cabling | Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used |
|
Bedding | Y | PVC as per JIS C 3401 |
Armor | C | Galvanized steel wire braid |
Core identification | 2C Black, White – 3C / 2C+E Black, White, Red/ Black, White, G/Y 4C / 3C+E Black, White, Red, Green /Black, White, Red, G/Y 5C and over Black No. on white insulation /Black No. on white insulation, G/Y |
|
Outer sheath color |
Black |
FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable Specification
0.6/1KV FR-DPYC 0.6/1KV FR-FA-DPYC
Conductor Size |
Conductor Construction |
Conductor O.D |
Nominal Cable OD |
Tolerance | Cable Weight |
mm2 | No./mm | mm | mm | mm | Kg / Km |
1.5 | 7/0.53 | 1.59 | 11.7 | 0.5 | 205 |
2.5 | 7/0.67 | 2.01 | 12.8 | 0.5 | 250 |
4 | 7/0.85 | 2.55 | 13.9 | 0.6 | 300 |
6 | 7/1.04 | 3.12 | 15.2 | 0.6 | 370 |
10 | 7/1.35 | 4.05 | 17.1 | 0.7 | 490 |
16 | 7/1.70 | 5.1 | 19.4 | 0.8 | 660 |
25 | 7/2.14 | 6.42 | 23 | 0.9 | 945 |
35 | 7/2.52 | 7.56 | 25.5 | 1 | 1200 |
50 | 19/1.78 | 8.9 | 29.4 | 1.2 | 1580 |
70 | 19/2.14 | 10.7 | 35.1 | 1.4 | 2300 |
95 | 19/2.52 | 12.6 | 39.1 | 1.6 | 2960 |
120 | 37/2.03 | 14.2 | 42.7 | 1.6 | 3600 |
150 | 37/2.25 | 15.8 | 46.8 | 1.7 | 4330 |
185 | 37/2.52 | 17.6 | 51.8 | 1.9 | 5330 |
0.6/1KV FR-TPYC 0.6/1KV FR-FA-TPYC
Conductor Size |
Conductor Construction |
Conductor O.D |
Nominal Cable OD |
Tolerance | Cable Weight |
mm² | No./mm | mm | mm | mm | Kg / Km |
1.5 | 7/0.53 | 1.59 | 12.5 | 0.5 | 245 |
2.5 | 7/0.67 | 2.01 | 13.5 | 0.5 | 295 |
4 | 7/0.85 | 2.55 | 14.7 | 0.6 | 365 |
6 | 7/1.04 | 3.12 | 16.1 | 0.6 | 455 |
10 | 7/1.35 | 4.05 | 18.3 | 0.7 | 625 |
16 | 7/1.70 | 5.1 | 20.8 | 0.8 | 855 |
25 | 7/2.14 | 6.42 | 24.7 | 1.0 | 1240 |
35 | 7/2.52 | 7.56 | 27.4 | 1.1 | 1600 |
50 | 19/1.78 | 8.9 | 32.0 | 1.3 | 2200 |
70 | 19/2.14 | 10.7 | 37.6 | 1.5 | 3050 |
95 | 19/2.52 | 12.6 | 41.9 | 1.6 | 3980 |
120 | 37/2.03 | 14.2 | 45.8 | 1.7 | 4860 |
150 | 37/2.25 | 15.8 | 50.2 | 1.8 | 5870 |
185 | 37/2.52 | 17.6 | 55.5 | 1.9 | 7230 |
240 | 61/2.25 | 20.25 | 62.7 | 2.3 | 10100 |
DISCLAIMER: Please note that the above specifications are “general specifications” that pertain to the majority of our production. Specifications and technical details should only be used for general, informational purposes only. For the actual specification, please check with us when order placed.