Products

S14 BU(c) Unarmoured FR Control Cable

Material: Cu/EPR/Cu Foil/SHF2
Voltage: 150/250V
APPLICATION: S14 BU(c) is an unarmored, fire resistant, collectively screened pairs or triples cables for fixed installation for instrumentation, communication, control and alarm systems in both EX- (Zone 2) and safe areas.

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V Application

S14 BU(c) Unarmoured Fire Resistant Control Cable is used for Instrument circuit up to 250V, instrument safe systems or in fixed installation instrument, communication, control and alarm systems in both explosion risk and safe areas, general purposes with special non-fire-propagation properties and low emission of opaque smoke and toxic and corrosives gases, oil resistant.

All materials used to manufacture this cable are halogen-free. This design ensures that non-corrosive and low toxic gas in case of fire, and ensures this cable can be used for living, quarter and office areas. This S14 BU(c) cable can be installed on drilling ships, drilling platforms ( jack up, semi-submersible), Production Platforms ( TLP, semi-submersible, SPAR, fixed platforms) and FPSO/FSO.

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V Standards

Design IEC60092-376, NEK TS 606:2009
Conductor IEC60228
Insulation IEC60092-351
sheathed IEC60092-359
Flame Retardant IEC 60332-1,IEC60332-3-22
Fire Resistant IEC 60331
Smoke Density IEC61034

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V Construction

Classification Code Construction details
Conductor Tinned Annealed Stranded Copper Wire
Insulation B Mica Tape+EP Rubber
Twinning Colour coded cores twisted together
Individual Shielding (i) Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.
Outer Sheath U Halogen free thermosetting compound, SHF2, colored grey (blue for intrinsically safe).

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V Electrical Characteristic

Nominal Cross Section Area mm^2 0.75 1.0 1.5
Nominal Conductor Diameter mm 1.1 1.3 1.6
Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9
Mutual Capacitance nF/km 75 80 85
Nominal Inductance@1KHz MH/km 0.727 0.686 0.667
Maximum L/R@1KHz μH/Ω 20 25 35
Operating Voltage V 250 250 250

S14 BU(c) Unarmoured Fire Resistant Control Cable 150/250V Specification

No. of elements×
No. of cores in element×
Cross section
Nominal
Insulation
Thickness
Nominal
Outer Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Weight
(mm2) mm mm mm kg/km
2×2×0.75 0.6 1.1 10.2 185
4×2×0.75 0.6 1.2 12.5 240
7×2×0.75 0.6 1.4 15.0 350
8×2×0.75 0.6 1.4 16.3 395
12×2×0.75 0.6 1.5 19.5 540
16×2×0.75 0.6 1.6 21.8 690
19×2×0.75 0.6 1.7 23.2 780
24×2×0.75 0.6 1.8 26.7 985
32×2×0.75 0.6 2.1 29.6 1225
2×3×0.75 0.6 1.2 12.0 205
3×3×0.75 0.6 1.2 13.1 265
4×3×0.75 0.6 1.3 14.4 320
7×3×0.75 0.6 1.3 17.4 475
8×3×0.75 0.6 1.5 19.5 590
12×3×0.75 0.6 1.6 22.9 745
16×3×0.75 0.6 1.7 25.6 965
19×3×0.75 0.6 1.8 27.2 1095
24×3×0.75 0.6 2.0 31.6 1405
2×2×1.0 0.6 1.1 10.7 210
4×2×1.0 0.6 1.1 13.3 285
7×2×1.0 0.6 1.4 16.0 415
8×2×1.0 0.6 1.4 17.3 465
12×2×1.0 0.6 1.6 20.8 645
16×2×1.0 0.6 1.7 23.3 825
19×2×1.0 0.6 1.8 24.7 940
24×2×1.0 0.6 1.9 28.8 1200
32×2×1.0 0.6 2.3 31.8 1495
3×3×1.0 0.6 1.2 14.0 310
4×3×1.0 0.6 1.4 15.3 380
7×3×1.0 0.6 1.6 18.6 570
12×3×1.0 0.6 1.6 24.4 900
16×3×1.0 0.6 1.7 27.3 1160
19×3×1.0 0.6 1.9 29.0 1325
24×3×1.0 0.6 2.1 33.7 1700
2×2×1.5 0.7 1.2 12.1 275
4×2×1.5 0.7 1.3 15.2 380
7×2×1.5 0.7 1.5 18.4 565
8×2×1.5 0.7 1.5 20.0 640
12×2×1.5 0.7 1.7 24.3 895
16×2×1.5 0.7 1.8 27.2 1150
19×2×1.5 0.7 1.9 28.6 1295
24×2×1.5 0.7 2.1 33.5 1670
32×2×1.5 0.7 2.3 37.0 2095
2×3×1.5 0.7 1.3 15.0 310
3×3×1.5 0.7 1.3 16.0 420
4×3×1.5 0.7 1.4 17.7 515
7×3×1.5 0.7 1.6 21.5 785
8×3×1.5 0.7 1.6 23.5 930
12×3×1.5 0.7 1.8 28.5 1255
16×3×1.5 0.7 1.9 31.9 1630
19×3×1.5 0.7 2.0 33.8 1855
24×3×1.5 0.7 2.2 39.3 2375

Please note that the above specifications are “general specifications” that pertain to the majority of our production. These specifications should only be used for general, informational purposes. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All specifications are subject to change without prior notice. All pictures shown are for illustration purposes only. Actual product may vary. Classification certification like CCS, DNV, BV, LR, NK, KR, RS shall be provided upon request.

Reviews

There are no reviews yet.

Be the first to review “S14 BU(c) Unarmoured FR Control Cable”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.