F-NTSCGEWOU EPR PCP High Voltage Fiber Optic Reeling Cable
F-NTSCGEWOU EPR PCP High Voltage Fiber Optic Reeling Cable Application
F-NTSCGEWOU H.V. flexible reeling cables are used in power supplies for connecting large equipment which may be moved from location to location for extremely high mechanical loads excavators, spreaders, loading bridges, portal cranes, construction equipment as well as for supplying power to heavy duty hoisting equipment, transport and conveyor systems, power supplies for building mains network sections in cases of power failure and similar applications.
F-NTSCGEWOU is flexible reeling cable with integrated fiber optic wires for high and extreme mechanical stresses, including torsional stress, deflection into different planes, and high reeling speed. Suitable for indoor and outdoor applications
F-NTSCGEWOU cables are suitable for installation in dry, moist and wet rooms as well as for outdoor installations and applications in locations with an associated explosion hazard, and building sites, in industrial workshops, open-face mining, in quarries. Trailing cables are primarily used in smelting foundries, limestone plants, sand and gravel excavation, container terminals, docks, and harbors, in brown coal excavation, salt and ore mining as in heavy industrial applications.
F-NTSCGEWOU EPR PCP High Voltage Reeling Cable Construction
Conductors | Flexible stranded copper conductor, class 5 according to DIN VDE 0295. |
Inner Conductor Layer | Semi-conductive layer. |
Insulation | EPR type 3GI3. |
Outer Conductor Layer | Semi-conductive layer. |
Earth Conductor | Split into two in the outer interstices. |
Inner Sheath | Rubber type GM1b/5GM3. |
Fiber Optics | 12 FO 50/125 or 62.5/125 or E9/125μm within protection sheath. |
Reinforcement | Polyester anti-torsion braid |
Outer Sheath | Rubber type 5GM3/5GM5, flame retardant and oil resistant. |
F-NTSCGEWOU EPR PCP High Voltage Reeling Cable Technical Data
Standards | DIN VDE 0250, Part 813 | ||||||
Rated voltage (Uo/U) | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 14/25 | 18/30 |
Maximum permissible operating voltage in AC systems (Uo/U) | 2.1/3.6 | 4.2/7.2 | 6.9/12 | 10.4/18 | 13.9/24 | 17.3/30 | 20.8/36 |
Maximum permissible operating voltage in DC systems (Uo/U) | 2.7/5.4 | 5.4/10.8 | 9/18 | 13.5/27 | 18/36 | 22.5/45 | 27/54 |
AC test voltage According to DIN VDE 0250, Part 813 | 6 | 11 | 17 | 24 | 29 | 36 | 43 |
Current carrying capacity | According to DIN VDE 0298, Part 4 Higher values are permissible in specific cases.Please consult the manufacturer. |
F-NTSCGEWOU EPR PCP High Voltage Reeling Cable Specification
No. of coresx cross-section | Outer-Ø ca. mm. | Copper weight | Cable weight approx. | Tensile strength | AWG |
n x mm2 | ± 10% | kg/km | kg/km | N | no.*) |
3.6/6 (7.2) kV F-NTSCGEWÖU OF | |||||
3×25+2×25/2+6LWL | 38.2 | 960 | 2635 | 1125 | 4 |
3×25+2×50/2+6LWL | 42.1 | 1200 | 3070 | 1125 | 4 |
3×35+2×25/2+6LWL | 42 | 1248 | 3055 | 1575 | 2 |
3×35+2×50/2+6LWL | 43.8 | 1488 | 3418 | 1575 | 2 |
3×50+2×25/2+6LWL | 45.3 | 1680 | 3503 | 2250 | 1 |
3×50+2×50/2+6LWL | 45.3 | 1920 | 3630 | 2250 | 1 |
3×70+2×25/2+6LWL | 48.5 | 2256 | 4340 | 3150 | 2/0 |
3×70+2×50/2+6LWL | 51.7 | 2496 | 5270 | 3150 | 2/0 |
3×95+2×50/2+6LWL | 54.2 | 3216 | 5540 | 4275 | 3/0 |
3×120+2×70/2+6LWL | 57.9 | 4128 | 7032 | 5400 | 4/0 |
3×150+2×70/2+6LWL | 63 | 4992 | 8010 | 6750 | 250MCM |
3×185+2×95/2+6LWL | 66 | 6240 | 9320 | 8325 | 350MCM |
3×240+2×120/2+6LWL | 74.1 | 8064 | 11930 | 10800 | 450MCM |
3×300+2×150/2+6LWL | 79.3 | 10080 | 14215 | 13500 | 550MCM |
6/10 (12) kV F-NTSCGEWÖU OF | |||||
3×25+2×25/2+6LWL | 42.9 | 960 | 2515 | 1125 | 4 |
3×25+2×50/2+6LWL | 44.6 | 1200 | 2945 | 1125 | 4 |
3×35+2×25/2+6LWL | 45.1 | 1248 | 2975 | 1575 | 2 |
3×35+2×50/2+6LWL | 46.2 | 1488 | 3340 | 1575 | 2 |
3×50+2×25/2+6LWL | 46.6 | 1680 | 3630 | 2250 | 1 |
3×50+2×50/2+6LWL | 48.3 | 1920 | 3790 | 2250 | 1 |
3×70+2×25/2+6LWL | 49.9 | 2256 | 4515 | 3150 | 2/0 |
3×70+2×50/2+6LWL | 54.7 | 2496 | 4740 | 3150 | 2/0 |
3×95+2×50/2+6LWL | 55.5 | 3216 | 5720 | 4275 | 3/0 |
3×120+2×70/2+6LWL | 59.2 | 4128 | 6875 | 5400 | 4/0 |
3×150+2×70/2+6LWL | 64.3 | 4992 | 8215 | 6750 | 250MCM |
3×185+2×95/2+6LWL | 68.3 | 6240 | 9518 | 8325 | 350MCM |
3×240+2×120/2+6LWL | 75.4 | 8064 | 12185 | 10800 | 450MCM |
3×300+2×150/2+6LWL | 80.6 | 10080 | 14522 | 13500 | 550MCM |
14/25 (30) kV F-NTSCGEWÖU OF | |||||
3×25+2×25/2+6LWL | 52.3 | 960 | 3740 | 1125 | 4 |
3×25+2×50/2+6LWL | 52.3 | 1200 | 3900 | 1125 | 4 |
3×35+2×25/2+6LWL | 55.1 | 1248 | 4270 | 1575 | 2 |
3×35+2×50/2+6LWL | 55.1 | 1488 | 4440 | 1575 | 2 |
3×50+2×25/2+6LWL | 58.3 | 1680 | 5000 | 2250 | 1 |
3×50+2×50/2+6LWL | 58.3 | 1920 | 5160 | 2250 | 1 |
3×70+2×25/2+6LWL | 63 | 2256 | 6190 | 3150 | 2/0 |
3×70+2×50/2+6LWL | 63 | 2496 | 6390 | 3150 | 2/0 |
3×95+2×50/2+6LWL | 67.3 | 3216 | 7340 | 4275 | 3/0 |
3×120+2×70/2+6LWL | 71 | 4128 | 8550 | 5400 | 4/0 |
3×150+2×70/2+6LWL | 76 | 4992 | 10020 | 6750 | 250 MCM |
3×185+2×95/2+6LWL | 79 | 6240 | 11410 | 8325 | 350 MCM |
3×240+2×120/2+6LWL | 87.5 | 8064 | 14380 | 10800 | 450 MCM |
3×300+2×150/2+6LWL | 92.7 | 10080 | 16820 | 13500 | 550 MCM |
18/30 (36) kV F-NTSCGEWÖU OF | |||||
3×25+2×25/2+6LWL | 55.7 | 960 | 4140 | 1125 | 4 |
3×25+2×50/2+6LWL | 55.7 | 1200 | 4310 | 1125 | 4 |
3×35+2×25/2+6LWL | 58.6 | 1248 | 4720 | 1575 | 2 |
3×35+2×50/2+6LWL | 58.6 | 1488 | 4880 | 1575 | 2 |
3×50+2×25/2+6LWL | 63.2 | 1680 | 5680 | 2250 | 1 |
3×50+2×50/2+6LWL | 63.2 | 1920 | 5840 | 2250 | 1 |
3×70+2×25/2+6LWL | 66.6 | 2256 | 6670 | 3150 | 2/0 |
3×70+2×50/2+6LWL | 66.6 | 2496 | 6870 | 3150 | 2/0 |
3×95+2×50/2+6LWL | 70.7 | 3216 | 7860 | 4275 | 3/0 |
3×120+2×70/2+6LWL | 75.8 | 4128 | 9350 | 5400 | 4/0 |
3×150+2×70/2+6LWL | 79.5 | 4992 | 10630 | 6750 | 250 MCM |
3×185+2×95/2+6LWL | 82.5 | 6240 | 12040 | 8325 | 350 MCM |
3×240+2×120/2+6LWL | 91 | 8064 | 15070 | 10800 | 450 MCM |
3×300+2×150/2+6LWL | 97.2 | 10080 | 17780 | 13500 | 550 MCM |
Reviews